      Photovoltaic Auto safety comprehensive tester

      Product Description:Name:Photovoltaic Auto safety comprehensive testerType:BND-CS9933EG-15Standards: IEC61730; IEC61215; IEC 61646Description of PV safety tester:Photovoltaic safety tester is used to test PV module, cable, connector, terminal box, …etc which can deal with high voltage and high sensitivity insulation test. There are two functions that are high voltage test and insulation resistance test in total.
      Description

      Product Description:

      Name:Photovoltaic Auto safety comprehensive tester

      Type:BND-CS9933EG-15

      Standards: IEC61730; IEC61215; IEC 61646


      Description of PV safety tester:

      Photovoltaic safety tester is used to test PV module, cable, connector, terminal box, …etc which can deal with high voltage and high sensitivity insulation test. There are two functions that are high voltage test and insulation resistance test in total.

      According to the IEC61730 standard(photovoltaic module safety qualification—part I: Requirements for construction which describes the fundamental construction requirements for photovoltaic modules in order to provide safe electrical and mechanical operation during their expected lifetime), the definition of PV module application is divided into A, B, C.

      The current measuring terminal can choose the grounding mode or the floating mode. Insulation voltage withstand test of photovoltaic module is based on the application of IEC61215/61646 and the maximum voltage of the system.

      Maximum test voltage for the application class A:2000V plus 4 times the maximum system voltage

      For the maximum voltage application category B:1000V system 2 times

      According to the calculation of a maximum voltage of 8000V, CS9923GS, CS9923G is based on this standard production

      According to the calculation of the maximum voltage B 6000V, CS9922G, CS9922GS is based on this standard production


      Performance characteristics:

      ◆With safety anti-electric wall function, it can automatically detect whether the input power is correct

      ◆For photovoltaic system panels, controllers, and battery packs

      ◆After the DC withstand voltage and insulation resistance tests are completed, the tester can quickly discharge within 0.2 seconds to protect the safety of the operator

      ◆With current lower limit alarm function, it can prevent the open circuit of the test line from causing misjudgment of the tested components during the test. The output voltage has voltage upper limit and voltage lower limit alarm functions

      ◆With keyboard lock function to prevent the operator from modifying the test parameters and ensure that the tested object is tested according to the set parameters

      ◆Linear power amplifier drives the output of sinusoidal voltage (current), and the crest factor is within the range of 1.3 to 1.5

      ◆Adopts 240*64 graphic LCD display and humanized interface design

      ◆With Chinese and English display interfaces, it can meet the different needs of different users.

      ◆Test parameters can be saved in advance: 30 files can be set, and each file can have 99 test steps

      ◆Optional RS232, RS485, USB interface, standard PLC interface

      pv-auto-safety-tester (1).jpg


      The Specification of the PV safety test system:

      Model

      BND-CS9933EG-15









      ACW


      The output voltage

      Range

      0.050kV~6.500kV

      Accuracy

      ±(1.5% reading + 5V)

      Resolution

      1V

      Maximum output power

      130VA(6.500kV/20mA)

      Maximum rated current

      20mA

      Lower current range

      0~20mA, 0=no lower limit

      Current range

      200uA, 2mA, 20mA

      Output waveform

      Sine wave

      Output waveform distortion

      ≤2% (no load or pure resistive load)

      Crest factor

      1.3~1.5

      Output signal type

      DDS+ amplifier

      Voltage rise time

      0.3s~999.9s 0=voltage rise time off

      Test time

      0.3s~999.9s 0=continuous test

      Voltage fall time

      0.3s~999.9s 0=voltage fall time off

      Interval time

      0.0s~999.9s 0=interval time off

      Output voltage mode

      N-mode, G-mode







      DCW






      The output voltage

      Range

      0.050kV~6.500kV

      Accuracy

      ±(1.5%Value +5V)

      Resolution

      1V

      Maximum output power

      65W(6.500kV/10mA)

      Maximum rated current

      10mA

      Current range

      2uA、20uA、200uA、2mA、10mA

      Ripple factor

      ≤5%

      Discharge time

      ≤200ms

      Maximum charge current

      10mA

      Voltage rise time

      0.3s~999.9s 0=voltage rise time off

      Test time

      0.3s~999.9s 0=continuous test

      Voltage drop time

      0.3s~999.9s 0=voltage drop time off

      Interval time

      0.0s~999.9s 0=interval time off

      Delay alarm time

      0.3s~999.9s 0=delay alarm time off

      Output voltage mode

      N mode, G mode


      IR



      The output voltage

      Range

      0.050kV~1.500kV

      Accuracy

      ±(1.5% reading +5V)

      Resolution

      1V

      Maximum upper limit setting value

      50.00GΩ




      Maximum and minimum setting values

      50.00GΩ

      Minimum setting values

      1MΩ

      Voltage rise time

      0.3~999.9s 0=voltage rise time off

      Test time

      0.3s~999.9s 0=continuous test

      Interval time

      0.0s~999.9s 0=interval time off

      Automatic gear switching

      Can be set to on or off

      Discharge time

      ≤200ms







      GR


      Output current

      Range

      3.00A~52.00A(DC)

      Accuracy

      ±(1.5% Value +0.2A)

      Resolution

      0.01A

      Maximum output power

      250W(50A/0.10Ω)

      Maximum output current

      50AW

      Resistance upper limit setting value

      40A x150mW

      Set current value

      Output waveform

      Sine wave

      Output waveform distortion

      ≤2% (no load or pure resistive load)

      Crest factor

      1.3~1.5

      Output signal type

      DDS+power amplifier

      Test time

      0.3s~999.9s 0=continuous test

      Interval time

      0.3s~999.9s 0=interval time off

      Voltmeter


      Range

      0.050kV~6.500kV

      0.050kV~6.500kV

      0.050kV~6.500kV

      0.050kV~6.500kV

      Accuracy

      ±(1.5% reading +5V)

      Resolution

      1V

      Display value

      RMS value



      Withstand voltage ammeter

      Measure range

      AC

      0 ~ 20mA

      DC

      0 ~ 10mA


      Resolution

      AC

      200uA: 0.1uA, 2mA: 1uA, 20mA: 10uA

      DC

      2uA: 0.001uA, 20uA: 0.01uA, 200uA: 0.1uA, 2mA: 1uA,

      10mA: 10uA

      Measurement accuracy

      ≥2mA: ±(1.5%+5 digits), <2mA: ±(2%+5 digits)

      Offset function

      The current of the test leads and accessories can be subtracted.

      Test mode

      GND mode: RETURN terminal connected to the chassis

      FLOAT mode: RETURN terminal not connected to the chassis


      Measurement range

      1MΩ~50000MΩ


      Resolution

      1MΩ~9.999MΩ:0.001MΩ,10MΩ~99.99MΩ:0.01MΩ,

      100MΩ~999.9MΩ:0.1MΩ,1000MΩ~9999MΩ:1MΩ

      10GΩ~50GΩ:10MΩ

      Insulation resistance meter



      Accuracy

      0.100kV~0.200kV:1MΩ~999MΩ ±5%,1000MΩ~3000MΩ ±10%

      0.201kV~0.499kV:1MΩ~999MΩ ±5%,1000MΩ~5000MΩ ±10%

      0.500kV~1.000kV:1MΩ~999MΩ ±5%,1000MΩ~9999MΩ ±10%

      10000MΩ~50000MΩ ±15%

      Ground current meter

      Measuring range

      3.00A~52.00A

      Resolution

      0.01A

      Accuracy

      ±(1.5% of reading + 0.2A)

      Display value

      RMS value

      Ground resistance meter

      Range

      0~510mΩ

      Accuracy

      When the current is less than 5.00A, it is ± (3% of reading + 3mΩ) When the current is ≥ 5.00A, it is ± (2% of reading + 2mΩ)

      Resolution

      0.1mΩ

      Measuring method

      Four-terminal method

      Timer

      Range

      0~999.9s

      Resolution

      0.1s

      Accuracy

      ±(0.1%+50ms)