<ol><code id="fJU3ISl"></code></ol>

  1. <em id="fJU3ISl"></em>

      UL 94 Horizontal and vertical flame test apparatus BND-SPR

      The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample‘s ignition and burning. Sex and fire hazard.
      Description

      Product Description:

      Name:UL 94 Horizontal and vertical flame test apparatus

      Type:BND-SPR


      The Basic introduction of the flame tester:

      1. The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample's ignition and burning. Sex and fire hazard.

      2. HVR-4 horizontal and vertical combustion tester is mainly used for grading assessment of the flammability of V-0, V-1, V-2, HB, and 5V materials. It is suitable for the research, production and quality inspection departments of electrical and electronic products and their components such as lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical meters, electrical connectors and accessories. Used in insulation materials, engineering plastics or other solid combustible materials industries.


      Technical Parameter of flame test:

      Model

      BND-SPR   Horizontal vertical flame tester

      Kinds

       500W(5V class )

       50W(HB/V class)

      Test Flame

      500W(burning test for V-0,V-1,V-2  classification)

      50W(burning test for V-0,V-1,V-2 classification)

      Burner Tube

      Internal diameter: Φ 9.5mm±0.3mm

      Internal diameter: Φ 9.5mm±0.3mm, 

      Burning Angle

      0°,20°,45°

      0°,20°,45°

      Thermocouple

      Type K (Ni/Cr - Ni/Al)

      Type K (Ni/Cr - Ni/Al)

      Thermocouple Size 

      0.5 mm

      0.5 mm

      Standard Copper Block 

      9mm±0.01mm,

      weight:10g±0.05g before drilling.  

      5.5mm±0.01mm,

      weight:76g±0.01g before drilling.

      Time for Temperature to Increase

      From 100°C±5°C to 700°C±3°C; 54s±2s (preset)

      From 100°C±5°C to 700°C±3°C;

      44s±2s (preset)

      Gas Flow

      965±32ml/min

      105±10ml/min

      Gas Supply

      methane,min.98% purity

      methane,min.98% purity

      water-column 

      125m±5mm

      ‹10mm

      Test  Time

      54±2s

      44±2s

      Flame Height Indicator

      40±1mm

      20±1mm

      Volume Of Chamber

      >0.5m³, black interior

      >0.5m³, black interior

      Conform to standard

      UL94,IEC60695-11-3,IEC60695-11-20

      UL94,IEC60695-11-4,IEC60695-11-10

      xBiMH

        <ol><code id="fJU3ISl"></code></ol>

      1. <em id="fJU3ISl"></em>