<ol><code id="fJU3ISl"></code></ol>

  1. <em id="fJU3ISl"></em>

      IK & IP Testing for Lighting Products

      2025-08-01

      IK & IP Testing for Lighting Products

      Ratings that demonstrate the degree of Impact Protection (IK) and Ingress Protection (IP) are critical for street, roadway and other lighting products. IP ratings are required per IEC/EN 60598-2-3 for all roadway and street applications. IK ratings are required in specific applications when high impact glass provides protection for the enclosed lamp.

      Standards

      IEC 62262 specifies the way enclosures should be tested for IK ratings which are defined as the level of protection the enclosures provided against external mechanical impacts. IEC 60598-1 (IEC 60529) specifies the test method used to classify and rate the degree of protection an enclosure provides against intrusion of various sized solid objects from fingers and hands to fine dust and the protection against water intrusion from falling drops to a high pressure water jet. IEC 60598-2-3 is the International Standard for Luminaires for Road and Street Lighting.

      UL offers complete testing and certification services for street and roadway luminaires to IEC 60598-2-3

      IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by electrical enclosures (including luminaires) against external mechanical impacts. The IK rating scale identifies the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating.

      Degrees if protection again external mechanical impacts

      IK00

      IK01

      IK02

      IK03

      IK04

      IK05

      IK06

      IK07

      IK08

      IK09

      IK10

      Non-protected

      0.14J

      0.2J

      0.35J

      0.5J

      0.7J

      1J

      2J

      5J

      10J

      20J

      1.jpg


      IP ratings are defined as IPXX where the first X indicates the degree of protection against solid objects and the second X indicates the degrees of protection against water. A luminaire or lighting component with a rating of IP66 is dust-tight and protected against powerful water jets as described in IEC 60598-1 (IEC 60529).]

      Degrees if protection again solid objects

      IP0X

      Non-protected

      IP1X

      50mm diameter and greater

      IP2X

      12.55mm diameter and greater

      IP3X

      2.5mm diameter and greater

      IP4X

      1.0mm diameter and greater

      IP5X

      Dust-protected

      IP6X

      Dust-tight

      2.jpg


      Degrees if protection again water

      IP0X

      Non-protected

      IP1X

      Vertically falling water drops

      IP2X

      Vertically falling water drops with enclosure tilted

      IP3X

      Spraying water

      IP4X

      Splashing water

      IP5X

      Water jets

      IP6X

      Powerful water jets

      IP7X

      Temporary immersion

      IP8X

      Continuous immersion